Add description to .tex files

parent dc09ca11
......@@ -489,12 +489,12 @@ Default values are:
With the use of a workflow file, you can define different FWI stages. For instance, one FWI stage could refer to one corner frequency of a low-pass filter or to a specific time window. Every line in the workflow file corresponds to one FWI stage. To use a workflow file the switch USE\_WORKFLOW have to be set to 1. The algorithm will automatically change to the next line of the workflow file if the abort criterium of the current line is reached or if no step length could be found which reduces the misfit. The structure of the variables inside the workflow file is as follow: \\
\noindent
\begin{tabular}{lllllllllllll}
\# & INV\_VS & INV\_VP & INV\_RHO & PRO & TIME\_FILT & F\_HIGH\_PASS & F\_LOW\_PASS & WAVETYPE & 0 & 0 & EPRECOND & EPSILON\_WE\\
\begin{tabular}{llllllllllIlll}
\# & INV\_VS & INV\_VP & INV\_RHO & PRO & TIME\_FILT & F\_HIGH\_PASS & F\_LOW\_PASS & WAVETYPE & 0 & 0 & EPRECOND & EPSILON\_WE & GAMMA \\
\end{tabular}
\ \\
The first column is the number of the line. With INV\_* etc. you can activate the inversion for VS, VP or RHO, respectively. The abort criterium in percent for this FWI stage will be the declared in the variable PRO. With TIME\_FILT you can activate the frequency filtering with the corner frequency F\_HIGH\_PASS of the high-pass and F\_LOW\_PASS of the low-pass filter. WAVETYPE can be used to switch between PSV and SH modeling, however it is recommended to use PSV modeling (WAVETYPE==1) due to the current development on SH modeling. The following to zeros are placeholders for an upcoming update. With EPRECOND and EPSILON\_WE you can control the approx. Hessian. Please note, that all features which are used eg. TIME\_FILT (see section \ref{sec:filtering}) within the workflow have to be activated in the .JSON file.
The first column is the number of the line. With INV\_* etc. you can activate the inversion for VS, VP or RHO, respectively. The abort criterium in percent for this FWI stage will be the declared in the variable PRO. With TIME\_FILT you can activate the frequency filtering with the corner frequency F\_HIGH\_PASS of the high-pass and F\_LOW\_PASS of the low-pass filter. WAVETYPE can be used to switch between PSV and SH modeling, however it is recommended to use PSV modeling (WAVETYPE==1) due to the current development on SH modeling. The following two zeros are placeholders for an upcoming update. With EPRECOND and EPSILON\_WE you can control the approx. Hessian. Please note, that all features which are used eg. With GAMMA you can define the exponential taper applied to both synthetic and observed data. TIME\_FILT (see section \ref{sec:filtering}) within the workflow have to be activated in the .JSON file.
For an example of a workflow file, have a look in the par/ folder.
......@@ -741,7 +741,7 @@ Default values are:
To apply time windowing in a time series the parameter TIMEWIN must set to 1. A automatic picker routine is not integrated. The point in time (picked time) for each source must be specified in separate files. The folder and file name can be set with the parameter PICKS\_FILE. The files must be named like this PICKS\_FILE\_<sourcenumber>.dat. So the number of sources must be equal to the number of files. Each file must contain the picked times for every receiver.
The parameters TWLENGTH\_PLUS and TWLENGTH\_MINUS specify the length of the time window after (PLUS) and before (MINUS) the picked time. The unit is seconds. The damping factor GAMMA must be set individually.
The parameters TWLENGTH\_PLUS and TWLENGTH\_MINUS specify the length of the time window after (PLUS) and before (MINUS) the picked time. The unit is seconds. The damping factor GAMMA must be set individually. In case where the workflow is used you can specify different values for GAMMA per stage.
When using TW\_IND = 1 three columns are expected in PICK\_FILE for each trace with the picked time (PT), time window length plus (TWLP) and time window length minus (TWLM). In this case TWLENGTH\_PLUS and TWLENGTH\_MINUS are ignored. It is also possible to use two time windows for each trace which can be utilized with TW\_IND = 2. PICK\_FILE must then contain six columns with values for PT\_1, TWLP\_1, TWLM\_1, PT\_2, TWLP\_2 and TWLM\_2 for each trace.
......
# VS VP RHO PRO F_FILT F_HIGH F_LOW WT J J EPRE EPSI
1 1 0 0 0.01 0 0 0 2 0 0 0 0.005
2 1 0 0 0.01 0 0 0 2 0 0 0 0.005
3 1 0 0 0.01 0 0 0 2 0 0 0 0.005
4 1 0 0 0.01 0 0 0 2 0 0 0 0.005
# VS VP RHO PRO F_FILT F_HIGH F_LOW WT J J EPRE EPSI GAMMA
1 1 0 0 0.01 0 0 0 2 0 0 0 0.005 20
2 1 0 0 0.01 0 0 0 2 0 0 0 0.005 10
3 1 0 0 0.01 0 0 0 2 0 0 0 0.005 5
4 1 0 0 0.01 0 0 0 2 0 0 0 0.005 0
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment